Two roofing sheets of the same thickness can last very different lengths of time. The difference is mostly in the metal coating under the paint: plain zinc (GI) or aluminium zinc (Galvalume). This guide explains the coating classes, what PPGI and PPGL mean, and how to read the marking printed on the back of the sheet.

Updated

In this guide
  1. GI: zinc coating (Z)
  2. Galvalume: aluminium zinc coating (AZ)
  3. PPGI vs PPGL
  4. Life in different conditions
  5. How to read the sheet marking
  6. Quick buying checklist

GI: zinc coating (Z)

GI (galvanised iron) sheet is steel coated with zinc, made to IS 277 in India. Zinc protects steel in two ways: it covers the steel, and when scratched or cut, it corrodes first and protects the exposed steel nearby. This is called sacrificial protection.

The coating is stated as mass per square metre, both faces together. Z120 means at least 120 g/m² total, Z180 means 180 g/m², and Z275 means 275 g/m². More zinc means longer life, roughly in proportion to the coating mass in the same atmosphere.

Galvalume: aluminium zinc coating (AZ)

Galvalume (also sold under brand names such as Zincalume) is steel coated with an alloy of about 55% aluminium, 43.4% zinc and 1.6% silicon. In India it is made to IS 15961. Coating classes are written with AZ, such as AZ70, AZ100, AZ150 and AZ200, again in g/m² on both faces together.

The aluminium forms a tough barrier that weathers very slowly, while the zinc gives some sacrificial protection. Because aluminium is much lighter than zinc, an AZ150 coating is thicker in microns than a Z150 would be. In most atmospheres an AZ coating lasts noticeably longer than a zinc coating of the same mass, which is why AZ150 is a common choice for good quality roofing.

  • Cut edges: AZ gives less sacrificial protection at cut edges than zinc, so some edge staining can appear. It is usually cosmetic but keep cut edges clean.
  • Avoid direct contact of bare Galvalume with wet cement mortar, concrete, copper, lead, or run-off from copper pipes.
  • Many makers advise against bare Galvalume in animal confinement buildings, because ammonia and manure attack it. For cattle and poultry sheds, ask the maker or use a painted sheet with a suitable warranty.

PPGI vs PPGL

PPGI is pre-painted galvanised iron: a GI base with a factory paint coat, made to IS 14246. PPGL is pre-painted Galvalume: an AZ base with a paint coat. Both are sold as colour coated sheets, so ask which base is underneath.

The paint protects the coating, and the coating protects the steel. When paint wears or gets scratched, the metal coating takes over. A PPGL sheet on AZ150 base will usually outlast a PPGI sheet on a thin zinc base once the paint has aged, which is why longer paint warranties are mostly offered on PPGL.

Life in different conditions

Life depends on coating mass, thickness, paint, and above all the air around the shed. The table gives general guidance on which coating to choose, not guaranteed life in years.

Choosing a coating by location (general guidance)
LocationMinimum sensible choiceBetter choice
Dry rural, store room or shopZ120 to Z180 GI or AZ70AZ150 or PPGL
House roof, general shedZ180 GI or AZ100AZ150 base PPGL
Farm with cattle or poultryZ275 GI, well paintedPainted sheet approved by maker for livestock use
Near brick kilns, factories, fumesZ275 or AZ150PPGL with higher paint class
Damp, low lying, near pondsZ275 or AZ150PPGL AZ150 with good paint

In west UP, brick kiln and industrial fumes and humid monsoon months are the main things that shorten sheet life. Spend on coating where those are present.

How to read the sheet marking

Branded sheets carry a printed line on the back at regular intervals. It typically shows the brand, the standard, the thickness, the coating class, the steel grade and a batch or coil number. For example, a marking may read something like: IS 15961, 0.45 mm BMT, AZ150, G550, then a coil number and date.

  • IS 277 means a GI (zinc) sheet. IS 15961 means Galvalume (AZ). IS 14246 is the colour coated standard on GI base.
  • Z or AZ followed by a number is the coating mass in g/m², both faces together.
  • BMT is the base steel thickness. TCT is total coated thickness including zinc and paint. Compare BMT to BMT.
  • G550 or G300 is the yield strength grade of the steel in MPa. High strength G550 is common for thin roofing profiles.
  • No marking at all is a warning sign. Ask for the bundle label or mill test certificate.

Quick buying checklist

  • Ask: GI or Galvalume base, and which Z or AZ class?
  • Ask: thickness in BMT, and the steel grade?
  • For colour coated: PPGI or PPGL, paint type and the written warranty terms.
  • Check the printed marking on a few sheets in the lot, not just one.
  • Store sheets dry and off the ground. Water trapped between stacked sheets causes white rust before the roof is even fixed.

Frequently asked questions

Is Galvalume better than GI?
In most atmospheres an AZ coating lasts longer than a zinc coating of the same mass. GI gives better protection at cut edges and is preferred where the sheet meets wet cement or animal waste. Choose by location.
Is AZ150 equal to Z275?
They are not directly equal, but in many conditions an AZ150 coating gives life similar to or better than Z275. Compare the maker's data for your conditions.
What is the difference between PPGI and PPGL?
Both are colour coated sheets. PPGI has a zinc (GI) base and PPGL has an aluminium zinc (Galvalume) base under the paint.
Where do I find the coating class on a sheet?
On the printed line on the back of branded sheets, or on the bundle label. It reads like Z275 or AZ150.

Related

Tell us the material, brand and quantity and we will send today's rate.

WhatsApp