Kumar IronGet rate

Lintel and chajja: size, steel bars and the top-bar rule

A lintel carries the wall over a door or window. A chajja (sunshade) is the thin slab that sticks out over the opening. Both are small, both are cast in a hurry, and both crack often when the steel is in the wrong place. Here is what is typical and what to check before the concrete goes in.

Updated

In this guide
  1. Consult your structural engineer first
  2. Lintel depth by opening span
  3. Bearing on the wall
  4. Chajja: why the main bars go on TOP
  5. Anchorage of chajja bars into the lintel
  6. Common mistakes

Consult your structural engineer first

Lintel and chajja sizes depend on the opening width, the wall load above, and whether a slab or beam sits on top. In seismic zone IV, which covers Amroha, IS 4326 also asks for a continuous lintel band in masonry walls. The figures below are common ranges only. Confirm with your structural engineer.

Lintel depth by opening span

Common lintel sizes for 230 mm walls, for orientation only
Clear openingCommon depthBottom barsTop barsStirrups
Up to 1.2 m (4 ft)150 mm (6 inch)2 nos 10 mm2 nos 8 mm6 mm or 8 mm at 150 mm
1.2 to 1.8 m (4 to 6 ft)150 to 230 mm2 or 3 nos 10 mm or 12 mm2 nos 8 mm or 10 mm8 mm at 150 mm
1.8 to 2.4 m (6 to 8 ft)230 to 300 mm3 nos 12 mm2 nos 10 mm8 mm at 125 to 150 mm
Over 2.4 mDesign as a beamAs per designAs per designAs per design

A rough check people use is depth of about one tenth to one twelfth of the span, but never less than 150 mm. Width equals the wall width.

Bearing on the wall

  • The lintel must rest on the wall on both sides by at least 150 mm, or the lintel depth, whichever is more. 200 to 230 mm is common practice.
  • In a lintel band the concrete runs continuously over all walls, so bearing is automatic and the band ties the walls together in an earthquake.
  • Do not let the lintel end on a half brick or on the edge of an opening next to it.

Chajja: why the main bars go on TOP

A chajja is a cantilever. It is held at one end and free at the other, so it bends downward and the top face is pulled in tension. Concrete is weak in tension, which is why the main bars must sit near the top of the chajja, with only about 15 to 20 mm cover from the top surface.

If the main bars sink to the bottom, the chajja has almost no steel where it needs it. It may look fine for months and then crack at the wall face or drop once props are removed.

  • Typical projection: 450 to 600 mm. Longer chajjas need design.
  • Typical thickness: about 100 mm at the wall, tapering to 75 mm at the edge.
  • Main bars: commonly 8 mm or 10 mm at 150 to 200 mm, at the top, running out from the wall.
  • Distribution bars: 6 mm or 8 mm at 200 to 250 mm, along the length, tied under the main bars.

Anchorage of chajja bars into the lintel

The chajja main bars must be anchored well back into the lintel or beam, not just touch it. They are commonly taken into the lintel and bent down, with the length set by the development length. For Fe500 bars in M20 concrete that works out to about 57 times the bar diameter, so about 450 mm for an 8 mm bar. For Fe415 it is about 47 times. Your engineer's drawing gives the exact detail.

A lintel carrying a chajja is also twisted by it. That is why a chajja should only come out of a lintel that has wall load or a slab above to hold it down, or a lintel designed for that twist.

Common mistakes

  • Chajja main bars placed at the bottom, or pushed down by workers walking on them during casting.
  • No cover blocks or chairs under the chajja bars to hold them up near the top.
  • Main bars stopped at the wall face with no anchorage into the lintel.
  • Props under the chajja removed too early. Cantilevers need the props longer than slabs.
  • Lintel bearing of just a few inches on each side.
  • Chajja cast separately days after the lintel with no proper joint or bar continuity.

Frequently asked questions

What is the minimum thickness of a lintel?
Usually 150 mm (6 inch) for small openings, increasing with span. Confirm with your structural engineer for openings over about 1.2 m.
Which steel is main steel in a chajja, top or bottom?
Top. A chajja is a cantilever, so the tension is at the top and the main bars go there, with distribution bars tied below them.
How much bearing should a lintel have?
At least 150 mm on each side, or the lintel depth if that is more. 200 to 230 mm is common.
When should chajja props be removed?
Cantilevers are kept propped longer than slabs, often around 14 days or as your engineer says. See our shuttering removal guide.

Related

Tell us the material, brand and quantity and we will send today's rate.

WhatsApp