Updated
In this guide
Consult your structural engineer first
Stirrup size and spacing are part of the structural design. Amroha and most of west UP are in seismic zone IV, where IS 13920 ductile detailing applies. The rules below explain what to look for on site. Confirm actual numbers with your structural engineer and follow the drawing.
Size of stirrups
- IS 456: a tie must be at least one quarter of the largest main bar diameter, and not less than 6 mm.
- So with main bars up to 24 mm, 6 mm is allowed on paper. With 25 mm or larger main bars, 8 mm is the minimum.
- In practice 8 mm is the usual size for house columns and beams, and many engineers do not use 6 mm in seismic zones.
- IS 13920 asks for at least 8 mm stirrups in beams with clear spans over 5 m.
Spacing rules
Try it: Column and beam steel calculator
Total steel: 41.3 kg (0.041 tonnes) for 1 beam, including 5% wastage
| Item | Quantity | Kg per member |
|---|---|---|
| Main bars 16 mm | 4 x 4.00 m | 25.3 |
| Stirrups 8 mm | 27 x 1.320 m | 14.1 |
| Per member, no wastage | 39.4 | |
| Per member, +5% | 41.3 |
| Member and zone | Spacing should not exceed the smallest of |
|---|---|
| Column, general (IS 456) | Least column side, 16 × smallest main bar diameter, 300 mm |
| Column, confining zone near joints (IS 13920) | ¼ of the smaller column side, 6 × smallest main bar diameter, 100 mm |
| Column, outside confining zone (IS 13920) | ½ of the smaller column side |
| Beam, general (IS 456) | 0.75 × effective depth, 300 mm |
| Beam, within 2 × depth from column face (IS 13920) | ¼ of effective depth, 6 × smallest main bar diameter, 100 mm |
| Beam, elsewhere (IS 13920) | ½ of effective depth |
Example: a 230 × 380 mm column with 12 mm main bars. Near joints: ¼ × 230 = 57.5 mm, 6 × 12 = 72 mm, 100 mm, so the limit is about 57 mm. In practice that is often detailed as 8 mm ties at 50 to 55 mm in the confining zones. Small columns need very close ties, which is one reason engineers prefer 300 mm or wider columns in zone IV.
Confining zones near joints
The ends of columns and beams, next to the joint, take the most damage in an earthquake. IS 13920 asks for close stirrups there.
- Column: over a length from each joint face of not less than the larger column side, one sixth of the clear column height, and 450 mm.
- Column ties continue through the beam column joint itself. This is the most commonly skipped step on site.
- Beam: over twice the beam depth from each column face, with the first stirrup within 50 mm of the face.
- Laps in column bars only in the middle half of the column height, with ties at 150 mm or closer over the lap.
- No laps of beam bars inside the joint or within twice the beam depth from it.
135° hooks, not 90°
Every stirrup in a seismic zone should close with 135° hooks at both ends, with a straight tail of 6 times the bar diameter but at least 65 mm, bent back into the core of the column or beam. For 8 mm stirrups, 6 × 8 = 48 mm, so the 65 mm minimum governs.
A 90° hook simply opens when the cover concrete spalls, and the stirrup stops working. Hooks should be staggered around the column, not all at the same corner.
Cutting length of a rectangular stirrup
Example: beam 230 × 300 mm, clear cover 25 mm, 8 mm stirrup with two 135° hooks. Site practice takes outer stirrup dimensions as size minus twice the cover, allows 10d per hook to cover the 65 mm tail and the bend, and deducts 2d per 90° bend and 3d per 135° bend.
| Step | Working | Result |
|---|---|---|
| Outer width | 230 − 2 × 25 | 180 mm |
| Outer depth | 300 − 2 × 25 | 250 mm |
| Perimeter | 2 × (180 + 250) | 860 mm |
| Two hooks | 2 × 10 × 8 | + 160 mm |
| Three 90° bends | 3 × 2 × 8 | − 48 mm |
| Two 135° bends | 2 × 3 × 8 | − 48 mm |
| Cutting length | about 924 mm |
Each stirrup weighs about 0.924 × 0.395 = 0.37 kg. Check one bent sample against the drawing before the bar bender cuts the whole lot, because bend allowances vary slightly with mandrel size.
Frequently asked questions
- What is the spacing of stirrups in a column?
- Outside joint zones, commonly 150 mm or as per drawing. Near joints in seismic zone IV, IS 13920 limits it to the smallest of ¼ of the smaller column side, 6 times the main bar diameter, and 100 mm. Confirm with your structural engineer.
- Why are stirrup hooks bent at 135 degrees?
- A 135° hook anchors into the confined core and stays closed when the outer concrete cracks. A 90° hook opens up in an earthquake.
- What is the hook length of an 8 mm stirrup?
- The tail should be 6 times the diameter but at least 65 mm, so 65 mm for 8 mm bar. Sites usually allow about 10d (80 mm) per hook in the cutting length.
- Can stirrups be 6 mm?
- IS 456 allows 6 mm when main bars are 24 mm or smaller, but 8 mm is the common choice in seismic zones. Follow the drawing.